Goniometer stage
Discontinued
Travel +/-6°
Table size 40mmx40mm
Resolution 0.000725°
YESRoHS対応状況

Product documentation

Description

Motorized goniometer (tilt) stage having a center of rotation on the space of the table.
Our unique hybrid coupling mechanism enables fine and very smooth operation.
V-groove and cross roller are used for guide.
It is widely used for precision positioning applications such as cameras and sensors.

Specifications

Direction of travel Tilt
Travel +/-6°
Table size 40mmx40mm
Motor Equivalent to PK523HPB (5-wire type pentagonal connection 0.75A/phase)
Resolution 0.000725°
Feed screw lead 0.5mm
Transfer mechanism Hybrid coupling mechanism / feed screws
Guiding method V-groove and Cross roller
Positioning accuracy 0.03°
Repeatability +/-0.002°
Stage height 18mm
Center of rotation 68mm
Positioning accuracy of rotatation center φ0.05mm
Lost motion 0.006°
Load capacity 29.4N (3kgf)
Weight 0.4kg
Maximum speed 3.6°/s
Material / Surface treatment Aluminum alloy / Black Alumite
HOME sensor Normally open contact (make contact, A contact) operation, Hall IC
*non-adjustable
LIMIT sensor Normally open contact (make contact, A contact) operation, Hall IC
*adjustable range : +/-6°
Compatible cable 0.75-B type (ACB-STM2, ACB-STM3, ACB-STM-D3, ARC-STM2, ARC-STM-D2, ARC-STM3 or ARC-STM-D3, be sold separately)
Standard accessories Inspection certificate
Mounting screw : M3 Hexagon socket head cap screws (4 pcs)
Dedicated parameter setting
(Parameter No.4)
31
Supplemental note About Positioning accuracy of hybrid coupling mechanism tilt stage :
Positioning accuracy of complex coupling mechanism