The QT-BDL1 is equipped as standard with general-purpose input and output, program channel selection input, drive pulse output, travel/stop determination output, program in-operation output, and program start/stop input ports. (However, program start/stop input must only be used with one of either general-purpose input or program channel selection input selected. Both cannot be selected at once. This must also be used with only one of either general-purpose output or travel/stop determination output selected. Both cannot be selected at the same time.)
The QT-BMM2, QT-BMH2, and QT-BMM3 are equipped with general-purpose input and output, program channel selection input, drive pulse input, drive pulse output, travel/stop determination output, program in-operation output, program start/stop input, and arbitrary step pulse output ports. With use in combination with the optional isolation interface (QT-AT), it is possible to connect to external devices.
(The QT-AT interface is required in order to use the I/O ports in models QT-BMM2, QT-BMH2, and QT-BMM3. I/O ports cannot be used if there is no QT-AT unit.QT-AT is required DC5 to 24V power supply.)